ISO 15848-1 fugitive emission testing: what it means and how it is verified

Tightness, endurance and temperature classes, the difference between a type test and a production test, and the inspector's checks during a helium test.

Farhad Tavakoli, Lead Inspector · November 2026 · 7 min read

Fugitive emission test with a helium leak detector on a control valve

What fugitive emissions are

They are small leaks of process fluid through the stem seal and the body joints of a valve. One valve leaks very little, but in a plant with thousands of valves the leaks become an environmental and safety issue. That is why many oil & gas and chemical specifications require valves qualified to ISO 15848-1 or API 624 / API 641.

The three classes in the standard

The result of an ISO 15848-1 qualification is expressed with three classes:

Tightness class

AH, BH, CH when the test uses helium; AM, BM, CM when it uses methane. A is the tightest class, typical of bellows seals; B and C are common for packed stems. With helium the leak rate is expressed in mbar·l/s per mm of stem diameter, with methane in ppmv measured by sniffing.

Endurance class

Number of mechanical open-close cycles performed during the test, together with thermal cycles: CO1, CO2, CO3 for isolating (on-off) valves, CC1, CC2, CC3 for control valves, which work with many more cycles.

Temperature class

The test is run at room temperature and at the declared temperatures, for example t(-46 °C) or t(200 °C). The qualification covers the range between the tested temperatures.

ISO 15848-1, ISO 15848-2 and API 624 / 641

A practical summary. The text of the standard in the edition named in the order always prevails.

AspectISO 15848-1ISO 15848-2API 624 / API 641
Type of testType test: qualifies a valve designProduction test on the valves suppliedType test: API 624 for rising-stem valves with graphite packing, API 641 for quarter-turn valves
Test fluidHelium or methaneHeliumMethane
Cycles and temperatureMechanical and thermal cycles according to the endurance and temperature classesNo cycles, at room temperatureMechanical and thermal cycles defined in the standard
AcceptanceTightness class achieved (AH…CH or AM…CM)Production class required by the orderLimit in ppmv set by the standard

A type test qualifies a design (valve type, size and pressure-class range, sealing system); it does not replace a production test on the valves you buy.

How to read the designation

An ISO 15848-1 certificate shows a designation such as “ISO FE BH – CO1 – SSA1 – t(RT, 200 °C) – CL300 – ISO 15848-1”: tightness class BH with helium, endurance class CO1, one stem seal adjustment allowed, tested at room temperature and at 200 °C, pressure class 300. Before accepting it, check that the certificate really covers the valve you are buying: type, stem diameter, pressure class, temperature and, above all, the same sealing system and packing.

What the inspector checks during the test

A checklist to use when witnessing a helium test. Adapt it to the approved procedure.

1. Before the test

  • Approved test procedure with required classes, pressure, temperatures and measuring points
  • Valve identified; packing or seal of the same type and manufacturer stated in the procedure
  • Helium leak detector (mass spectrometer) calibrated, and calibrated reference leak with a valid certificate
  • Pressure gauges and thermocouples calibrated, with a suitable range

2. During the measurement

  • Helium background measured and recorded before the test
  • Detector checked against the reference leak before and after the measurements
  • Method and probe position as per procedure (enclosure on the stuffing box, or probe at the body seals)
  • Values recorded in the correct units, with the stem diameter used for the calculation

3. During the cycles (type test)

  • Mechanical cycles counted and recorded
  • Thermal cycle temperatures recorded
  • Every stem seal adjustment recorded and compared with the SSA class

4. Report

  • Measured leak rates for each point and stage, class achieved compared with the class required
  • Serial numbers of detector, reference leak and instruments; photos of the test

The non-conformities we find most often

  • Detector not checked against the reference leak before measuring
  • High helium background in the test area, not recorded
  • Packing different from the one in the qualification
  • Stem seal adjustments not recorded, or more than the SSA class allows
  • Type-test certificate presented for a valve it does not cover (different size, class or temperature)

Our experience

We have witnessed fugitive emission tests with helium and a mass-spectrometer leak detector on control valves at the Baker Hughes – Nuovo Pignone plant in Bari. The report records measured values, instruments, photos and, when everything conforms, the Inspection Release Note.

Read the case study